Two Place System with EDS-O2D2-2G Kit, DIN-477 Regulator with Gauge, CFF-480 (18.2 cu. ft.) Silica (Glass) Fiber Wrapped Cylinder and Full-Pack

O2D2: The O2D2 has 2 unique features distinct from the O2D1 which are the option for external power input and audio output. The EDS unit supplies the oxygen you need to stay alert and comfortable while flying by providing a measured pulse of oxygen at the beginning of each inhalation. In contrast to constant flow systems that deliver more oxygen than the body needs, the MH EDS provides oxygen only when you inhale. This patented delivery technology ensures that you stay safe and comfortable by delivering the proper amount of oxygen based on your pressure altitude and breathing rate. The efficiency of this method provides a dramatic increase in cylinder duration, which enables you to enjoy the benefits of oxygen use below the mandated altitude. This means fewer headaches, less fatigue and increased alertness when flying at night or for long distances. It also enables you to save weight and space with a smaller cylinder, and fly longer between refills!

Unlike constant-flow oxygen systems, the MH EDS features “set and forget” operation and can be set to begin providing oxygen either immediately, or above a specified altitude. Oxygen flow is automatically adjusted according to your pressure altitude. When you’re flying, you have more important things to do than adjust your oxygen flow during altitude changes.

Duration Table (hours)
 Cylinder 

Fill Pressure

Volume

Diameter
Max.
Length
Max.
Weight
Empty

Duration in Hours
(2 Place)

 barPSI liters cu. ft.cminchcminchKg lb 10K ft  15K ft  18K ft 
CFF-480 124180030910.9 11.434.5040.0015.751.874.1259.54.63.5
CFF-480 207  3000 51518.2  11.43  4.50  40.00  15.75  1.87  4.125 15.87.76.0

Our new Pulse Demand (2G) systems still incorporate all of the benefits of our legacy controllers but with many improvements. Like the series of the old VW Beetle, it’s the same, but better.

We started with the control switch: The EDS unit now incorporates a MIL spec rugged, easy-to- grip, rotary control switch providing improved reliability, increased ease of function and visibility. This switch also has very positive position detentes for excellent tactile feedback making it resistant to changes from causal rubbing or bumping.

While we were at it, we improved the manifold design to allow for better breathing response and effort tracking. This, combined with a new circuit board, as well as a new micro-controller, gives improved power-conserving operations with even less RFI emissions, better respire-metric tracking and dispensing of oxygen in finer resolution resulting in smoother steps from altitude and breathing changes.

Other improvements include a dedicated bi-color system battery status light allowing much easier monitoring and definitive indication of battery condition without being confused as a station operation. The original O2Dx units encoded the low battery notification into the station lights. This status light also responds to each control switch change with a beep and green flash to confirm your actions. Also the audio alerts and warnings are louder, more crisp and dynamic to human hearing in an effort of being heard over modest cabin noise. The O2D2 has a 600 Ohm stereo external audio jack as well as a USB compatible (5VDC) external power port.

More intuitive F-Mode settings labeled as 1, 2, 3 & 4 for use with face masks or when more oxygen is required.

How Pulse Demand Works

   The patented MH EDS (Electronic Delivery System) is a one (O2D1-2G) or two-user (O2D2-2G) aviation oxygen delivery device. It is designed to deliver aviation oxygen in the most efficient, comfortable and convenient way possible. With its selectable settings, apnea alarm and small size, the MH EDS is the most portable and flexible electronic digital oxygen delivery system in the world. By providing a measured pulse of oxygen every time you breathe in, the MH EDS supplies the oxygen you need to stay alert and comfortable while flying. In contrast to constant flow systems that waste oxygen by supplying more than your body can use, the MH EDS provides a short pulse of oxygen as you inhale, ensuring that your oxygen is used most efficiently. Efficient oxygen delivery means you can fly further on a single oxygen refill or save space and weight with a smaller tank. It also makes it more feasible to enjoy the advantages of oxygen while flying below the altitudes where oxygen is mandated– that can mean fewer headaches, increased alertness, and feeling less exhausted when you reach your destination. Your actual oxygen usage will be determined by your breathing rate and physiological needs at altitude. The programmability of the MH EDS means that, unlike constant-flow oxygen systems, you can “set it and forget it”. By automatically detecting your pressure altitude, the MH EDS can be set to start providing oxygen immediately or at a specified altitude and will automatically adjust the oxygen flow as your altitude changes. When you’re flying, don’t you have more important things to do than adjust your oxygen flow during altitude changes?

Items included in EDS-O2D2-2G Breathing System Kits





CFF-480 
Silica (Glass) 
Wrapped
 Cylinder

  EDS O2D2-2G Unit    2 or 4  EDS Cannulas  
(standard tip)
00EDS-1084-00
 1 or 2 EDS Cannulas 
(flare tip)
00EDS-1084-01
 2 or 4 EDS Face Masks 
00EDS-1078-00
 




 EDS to XCP Coupler Kit  
Tote Bag, 12" x 12"
 60000-0012-00
 00REG-1034-02
and red tubing from 
regulator to O2D2

Full-Pack

3 AAA
Batteries

Not Included:

  • Oxygen - The oxygen tank is empty.

To add extra flow stations to any of the 2-place O2D2-2G systems below, add $100 for the FPR 4-place regulator upgrade.
See our 
Full-Pack cylinder harness & carry-caddy for these cylinders. Also see CMK cylinder hold-down kits.
Also, the optional ALPS FaceMask with or without microphone is the perfect addition to any EDS system.

Product Manual:
EDS 02D2-2G User Manual Rev. -1 

Related Documents:
Oxygen Cylinder Dimensions and Duration Table
EDS Oxygen Information
CAMI Testing of Pulse Oxygen Systems
CAMI Altitude Chamber Profile
Mountain High Documents Page - Manuals, specifications, articles, etc.
EDS O2D1 Specifications

Specifications
O2D2 DIM(md)
EDS-O2D2 Audio Wiring 5IEDS-0020-00(02D20-150-000$-0)[SCD](md)

Write a review

Note: HTML is not translated!
    Bad           Good

MH-00EDS-2084-D2

  • Brand: Mountain High
  • Product Code: O2D2-480-2P-DIN-F
  • Availability: In Stock
  • $2,195.00


Related Products

MH-00EDS-1070-00

MH-00EDS-1070-00

Adapter to Connect EDS Unit to XCP RegulatorXCP to EDS Feed Tube for CPC type connection.EDS-XCP ada..

$10.00

MH-00EDS-1078-00

MH-00EDS-1078-00

Face Mask for EDS SystemsFace mask for the EDS pulse demand systems.  For use above 18,000..

$13.50

MH-00EDS-1084-00

MH-00EDS-1084-00

Cannula for EDS Systems - Standard Tip VersionEDS Replacement Cannula.  This item is included w..

$11.00

MH-00EDS-1084-01

MH-00EDS-1084-01

Cannula for EDS Systems - Flare Tip VersionEDS Replacement Cannula.  This item is included with..

$11.00

MH-60000-0012-00

MH-60000-0012-00

Tote BagHandy 12″ X 12″ zippered fabric tote bag for storing cannulas, face masks, flowmeters or oth..

$7.50

MH-00FAB-00xx

MH-00FAB-00xx

Full-Pack Padded Carrying Case for Portable CylindersA fully padded carry case for any of our portab..

$99.00

MH-00REG-1018-02

MH-00REG-1018-02

XCR-4P, Four Place CGA-540 Regulator FPR-REG-CGA540-no gaugeCGA-540 port for oxygen cylinder an..

$425.00

MH-00REG-2110-04

MH-00REG-2110-04

REG 2G, 1-place Axial Regulator, No GaugeDIN 477-9 Euro inlet, 4mm Push-to-Connect axial outlet, Non..

$305.00

MH-00EDS-1092-00

MH-00EDS-1092-00

Cannula, E-Z Breathe-II Boom Cannula for EDS-Pulse Demand (One Touch) connector.The E-Z Breathe..

$99.00

Tags: 00EDS-2084-D2